proxmark3/doc/cloner_notes.md

82 lines
2.5 KiB
Markdown
Raw Normal View History

2020-11-29 08:35:12 +08:00
# Notes on Cloner guns
This document is based mostly on information posted on http://www.proxmark.org/forum/viewtopic.php?pid=39903#p39903
- [Notes on Cloner guns](#notes-on-cloner-guns)
- [Blue and black cloners](#blue-and-black-cloners)
- [White cloner (pre 2015)](#white-cloner-pre-2015)
- [White cloner (after 2016)](#white-cloner-after-2016)
- [White cloner (after 2016 D Quality)](#white-cloner-after-2016-d-quality)
- [Restore page1 data](#restore-page1-data)
- [Sniffing the comms](#sniffing-the-comms)
# Blue and black cloners
3 variants:
1. EM cloner
2. HID cloner
3. EM/HID cloner
Quality varies my manufacturer (Quality A (Good) until D (Bad))
They set a password on block 7 of the chip and set the password enable bit in block 0
```
Standard password is normally: 51243648
```
**Be sure to purchase the EM/HID version**
# White cloner (pre 2015)
Multifrequency
Buttons light up BLUE
Reads data correctly
Coil performance acceptable
```
Standard password is normally (for T55xx): AA55BBBB
Standard password 13,56mHz: individual per white cloner
```
# White cloner (after 2016)
Multifrequency
Buttons light up WHITE
Data scrambled (variable per individual cloner, possibly due to prevent legal issues)
Coil performance good
```
Standard password is normally (for T55xx): AA55BBBB
Standard password 13,56mHz: individual per white cloner
```
# White cloner (after 2016 D Quality)
Multifrequency (it says so but it doesn't)
Only works for EM/HID card (125kHz)
High frequency not working
```
Standard password is normally (for T55xx): AA55BBBB
```
**Note: Sets the HID card in TEST MODE**
# Restore page1 data
```
2021-03-08 05:00:33 +08:00
lf t55xx write -b 1 -d E0150A48 --pg1
If t55xx write -b 2 -d 2D782308 --pg1
2020-11-29 08:35:12 +08:00
```
# Sniffing the comms
The T55x7 protocol uses a pwm based protocol for writing to tags. In order to make decoding easier try the new command as seen below instead. It will try to extract the data written.
```
-- after threshold limit 20 is triggered, skip 10000 samples before collecting samples.
2021-03-08 18:31:40 +08:00
lf config -s 10000 -t 20
2020-11-29 08:35:12 +08:00
lf t55xx sniff
-- if you have a save trace from before, try
data load -f xxxxxxx.pm3
2021-03-08 18:31:40 +08:00
lf t55xx sniff -1
2020-11-29 08:35:12 +08:00
```
It uses the existing `lf sniff` command to collect the data, so setting that first as per normal sniffing is recommended. Once you have a sniff, you can "re-sniff" from the stored sniffed data and try different settings, if you think the data is not clean.
2020-09-17 12:53:27 +08:00
As normal, the cloner may write data past the end of the 40K sample buffer. So using the `lf config s <x bytes>` then re-run the sniff to see if there is more data.