fix: 'hw connect' - if pm3 client was in offline more to start with, check..

This commit is contained in:
iceman1001 2019-05-07 12:28:17 +02:00
parent a20392edf3
commit f85280ad41

View file

@ -508,14 +508,20 @@ static int CmdConnect(const char *Cmd) {
// default back to previous used serial port
if (strlen(port) == 0 )
GetSavedSerialPortName( &port );
if ( port == NULL ) {
return usage_hw_connect();
}
// if we were already connected, disconnect first.
if (session.pm3_present) {
//if (session.pm3_present) {
PrintAndLogEx(INFO, "Disconnecting from current serial port");
CloseProxmark();
session.pm3_present = false;
}
//}
// set timeouts
//int res = uart_reconfigure_timeouts(sp, UART_USB_CLIENT_RX_TIMEOUT_MS);
// try to open serial port
session.pm3_present = OpenProxmark(port, false, 20, false, USART_BAUD_RATE);