//----------------------------------------------------------------------------- // Copyright (C) 2017 Merlok // // This code is licensed to you under the terms of the GNU GPL, version 2 or, // at your option, any later version. See the LICENSE.txt file for the text of // the license. //----------------------------------------------------------------------------- // APDU status bytes information //----------------------------------------------------------------------------- #include "apduinfo.h" const APDUCode APDUCodeTable[] = { // ID Type Description {"XXXX", APDUCODE_TYPE_NONE, ""}, // blank string {"6---", APDUCODE_TYPE_ERROR, "Class not supported."}, {"61--", APDUCODE_TYPE_INFO, "Response bytes still available"}, {"61XX", APDUCODE_TYPE_INFO, "Command successfully executed; 'XX' bytes of data are available and can be requested using GET RESPONSE."}, {"62--", APDUCODE_TYPE_WARNING, "State of non-volatile memory unchanged"}, {"6200", APDUCODE_TYPE_WARNING, "No information given (NV-Ram not changed)"}, {"6201", APDUCODE_TYPE_WARNING, "NV-Ram not changed 1."}, {"6281", APDUCODE_TYPE_WARNING, "Part of returned data may be corrupted"}, {"6282", APDUCODE_TYPE_WARNING, "End of file/record reached before reading Le bytes"}, {"6283", APDUCODE_TYPE_WARNING, "Selected file invalidated"}, {"6284", APDUCODE_TYPE_WARNING, "Selected file is not valid. FCI not formated according to ISO"}, {"6285", APDUCODE_TYPE_WARNING, "No input data available from a sensor on the card. No Purse Engine enslaved for R3bc"}, {"62A2", APDUCODE_TYPE_WARNING, "Wrong R-MAC"}, {"62A4", APDUCODE_TYPE_WARNING, "Card locked (during reset( ))"}, {"62CX", APDUCODE_TYPE_WARNING, "Counter with value x (command dependent)"}, {"62F1", APDUCODE_TYPE_WARNING, "Wrong C-MAC"}, {"62F3", APDUCODE_TYPE_WARNING, "Internal reset"}, {"62F5", APDUCODE_TYPE_WARNING, "Default agent locked"}, {"62F7", APDUCODE_TYPE_WARNING, "Cardholder locked"}, {"62F8", APDUCODE_TYPE_WARNING, "Basement is current agent"}, {"62F9", APDUCODE_TYPE_WARNING, "CALC Key Set not unblocked"}, {"62FX", APDUCODE_TYPE_WARNING, "-"}, {"62XX", APDUCODE_TYPE_WARNING, "RFU"}, {"63--", APDUCODE_TYPE_WARNING, "State of non-volatile memory changed"}, {"6300", APDUCODE_TYPE_WARNING, "No information given (NV-Ram changed)"}, {"6381", APDUCODE_TYPE_WARNING, "File filled up by the last write. Loading/updating is not allowed."}, {"6382", APDUCODE_TYPE_WARNING, "Card key not supported."}, {"6383", APDUCODE_TYPE_WARNING, "Reader key not supported."}, {"6384", APDUCODE_TYPE_WARNING, "Plaintext transmission not supported."}, {"6385", APDUCODE_TYPE_WARNING, "Secured transmission not supported."}, {"6386", APDUCODE_TYPE_WARNING, "Volatile memory is not available."}, {"6387", APDUCODE_TYPE_WARNING, "Non-volatile memory is not available."}, {"6388", APDUCODE_TYPE_WARNING, "Key number not valid."}, {"6389", APDUCODE_TYPE_WARNING, "Key length is not correct."}, {"63C0", APDUCODE_TYPE_WARNING, "Verify fail, no try left."}, {"63C1", APDUCODE_TYPE_WARNING, "Verify fail, 1 try left."}, {"63C2", APDUCODE_TYPE_WARNING, "Verify fail, 2 tries left."}, {"63C3", APDUCODE_TYPE_WARNING, "Verify fail, 3 tries left."}, {"63CX", APDUCODE_TYPE_WARNING, "The counter has reached the value 'x' (0 = x = 15) (command dependent)."}, {"63F1", APDUCODE_TYPE_WARNING, "More data expected."}, {"63F2", APDUCODE_TYPE_WARNING, "More data expected and proactive command pending."}, {"63FX", APDUCODE_TYPE_WARNING, "-"}, {"63XX", APDUCODE_TYPE_WARNING, "RFU"}, {"64--", APDUCODE_TYPE_ERROR, "State of non-volatile memory unchanged"}, {"6400", APDUCODE_TYPE_ERROR, "No information given (NV-Ram not changed)"}, {"6401", APDUCODE_TYPE_ERROR, "Command timeout. Immediate response required by the card."}, {"64XX", APDUCODE_TYPE_ERROR, "RFU"}, {"65--", APDUCODE_TYPE_ERROR, "State of non-volatile memory changed"}, {"6500", APDUCODE_TYPE_ERROR, "No information given"}, {"6501", APDUCODE_TYPE_ERROR, "Write error. Memory failure. There have been problems in writing or reading the EEPROM. Other hardware problems may also bring this error."}, {"6581", APDUCODE_TYPE_ERROR, "Memory failure"}, {"65FX", APDUCODE_TYPE_ERROR, "-"}, {"65XX", APDUCODE_TYPE_ERROR, "RFU"}, {"66--", APDUCODE_TYPE_SECURITY, " "}, {"6600", APDUCODE_TYPE_SECURITY, "Error while receiving (timeout)"}, {"6601", APDUCODE_TYPE_SECURITY, "Error while receiving (character parity error)"}, {"6602", APDUCODE_TYPE_SECURITY, "Wrong checksum"}, {"6603", APDUCODE_TYPE_SECURITY, "The current DF file without FCI"}, {"6604", APDUCODE_TYPE_SECURITY, "No SF or KF under the current DF"}, {"6669", APDUCODE_TYPE_SECURITY, "Incorrect Encryption/Decryption Padding"}, {"66XX", APDUCODE_TYPE_SECURITY, "-"}, {"67--", APDUCODE_TYPE_ERROR, " "}, {"6700", APDUCODE_TYPE_ERROR, "Wrong length"}, {"67XX", APDUCODE_TYPE_ERROR, "length incorrect (procedure)(ISO 7816-3)"}, {"68--", APDUCODE_TYPE_ERROR, "Functions in CLA not supported"}, {"6800", APDUCODE_TYPE_ERROR, "No information given (The request function is not supported by the card)"}, {"6881", APDUCODE_TYPE_ERROR, "Logical channel not supported"}, {"6882", APDUCODE_TYPE_ERROR, "Secure messaging not supported"}, {"6883", APDUCODE_TYPE_ERROR, "Last command of the chain expected"}, {"6884", APDUCODE_TYPE_ERROR, "Command chaining not supported"}, {"68FX", APDUCODE_TYPE_ERROR, "-"}, {"68XX", APDUCODE_TYPE_ERROR, "RFU"}, {"69--", APDUCODE_TYPE_ERROR, "Command not allowed"}, {"6900", APDUCODE_TYPE_ERROR, "No information given (Command not allowed)"}, {"6901", APDUCODE_TYPE_ERROR, "Command not accepted (inactive state)"}, {"6981", APDUCODE_TYPE_ERROR, "Command incompatible with file structure"}, {"6982", APDUCODE_TYPE_ERROR, "Security condition not satisfied."}, {"6983", APDUCODE_TYPE_ERROR, "Authentication method blocked"}, {"6984", APDUCODE_TYPE_ERROR, "Referenced data reversibly blocked (invalidated)"}, {"6985", APDUCODE_TYPE_ERROR, "Conditions of use not satisfied."}, {"6986", APDUCODE_TYPE_ERROR, "Command not allowed (no current EF)"}, {"6987", APDUCODE_TYPE_ERROR, "Expected secure messaging (SM) object missing"}, {"6988", APDUCODE_TYPE_ERROR, "Incorrect secure messaging (SM) data object"}, {"698D", APDUCODE_TYPE_NONE, "Reserved"}, {"6996", APDUCODE_TYPE_ERROR, "Data must be updated again"}, {"69E1", APDUCODE_TYPE_ERROR, "POL1 of the currently Enabled Profile prevents this action."}, {"69F0", APDUCODE_TYPE_ERROR, "Permission Denied"}, {"69F1", APDUCODE_TYPE_ERROR, "Permission Denied - Missing Privilege"}, {"69FX", APDUCODE_TYPE_ERROR, "-"}, {"69XX", APDUCODE_TYPE_ERROR, "RFU"}, {"6A--", APDUCODE_TYPE_ERROR, "Wrong parameter(s) P1-P2"}, {"6A00", APDUCODE_TYPE_ERROR, "No information given (Bytes P1 and/or P2 are incorrect)"}, {"6A80", APDUCODE_TYPE_ERROR, "The parameters in the data field are incorrect."}, {"6A81", APDUCODE_TYPE_ERROR, "Function not supported"}, {"6A82", APDUCODE_TYPE_ERROR, "File not found"}, {"6A83", APDUCODE_TYPE_ERROR, "Record not found"}, {"6A84", APDUCODE_TYPE_ERROR, "There is insufficient memory space in record or file"}, {"6A85", APDUCODE_TYPE_ERROR, "Lc inconsistent with TLV structure"}, {"6A86", APDUCODE_TYPE_ERROR, "Incorrect P1 or P2 parameter."}, {"6A87", APDUCODE_TYPE_ERROR, "Lc inconsistent with P1-P2"}, {"6A88", APDUCODE_TYPE_ERROR, "Referenced data not found"}, {"6A89", APDUCODE_TYPE_ERROR, "File already exists"}, {"6A8A", APDUCODE_TYPE_ERROR, "DF name already exists."}, {"6AF0", APDUCODE_TYPE_ERROR, "Wrong parameter value"}, {"6AFX", APDUCODE_TYPE_ERROR, "-"}, {"6AXX", APDUCODE_TYPE_ERROR, "RFU"}, {"6B--", APDUCODE_TYPE_ERROR, " "}, {"6B00", APDUCODE_TYPE_ERROR, "Wrong parameter(s) P1-P2"}, {"6BXX", APDUCODE_TYPE_ERROR, "Reference incorrect (procedure byte), (ISO 7816-3)"}, {"6C--", APDUCODE_TYPE_ERROR, "Wrong length Le"}, {"6C00", APDUCODE_TYPE_ERROR, "Incorrect P3 length."}, {"6CXX", APDUCODE_TYPE_ERROR, "Bad length value in Le; 'xx' is the correct exact Le"}, {"6D--", APDUCODE_TYPE_ERROR, " "}, {"6D00", APDUCODE_TYPE_ERROR, "Instruction code not supported or invalid"}, {"6DXX", APDUCODE_TYPE_ERROR, "Instruction code not programmed or invalid (procedure byte), (ISO 7816-3)"}, {"6E--", APDUCODE_TYPE_ERROR, " "}, {"6E00", APDUCODE_TYPE_ERROR, "Class not supported"}, {"6EXX", APDUCODE_TYPE_ERROR, "Instruction class not supported (procedure byte), (ISO 7816-3)"}, {"6F--", APDUCODE_TYPE_ERROR, "Internal exception"}, {"6F00", APDUCODE_TYPE_ERROR, "Command aborted - more exact diagnosis not possible (e.g., operating system error)."}, {"6FFF", APDUCODE_TYPE_ERROR, "Card dead (overuse)"}, {"6FXX", APDUCODE_TYPE_ERROR, "No precise diagnosis (procedure byte), (ISO 7816-3)"}, {"9---", APDUCODE_TYPE_NONE, ""}, {"9000", APDUCODE_TYPE_INFO, "Command successfully executed (OK)."}, {"9004", APDUCODE_TYPE_WARNING, "PIN not succesfully verified, 3 or more PIN tries left"}, {"9008", APDUCODE_TYPE_NONE, "Key/file not found"}, {"9080", APDUCODE_TYPE_WARNING, "Unblock Try Counter has reached zero"}, {"9100", APDUCODE_TYPE_NONE, "OK"}, {"9101", APDUCODE_TYPE_NONE, "States.activity, States.lock Status or States.lockable has wrong value"}, {"9102", APDUCODE_TYPE_NONE, "Transaction number reached its limit"}, {"910C", APDUCODE_TYPE_NONE, "No changes"}, {"910E", APDUCODE_TYPE_NONE, "Insufficient NV-Memory to complete command"}, {"911C", APDUCODE_TYPE_NONE, "Command code not supported"}, {"911E", APDUCODE_TYPE_NONE, "CRC or MAC does not match data"}, {"9140", APDUCODE_TYPE_NONE, "Invalid key number specified"}, {"917E", APDUCODE_TYPE_NONE, "Length of command string invalid"}, {"919D", APDUCODE_TYPE_NONE, "Not allow the requested command"}, {"919E", APDUCODE_TYPE_NONE, "Value of the parameter invalid"}, {"91A0", APDUCODE_TYPE_NONE, "Requested AID not present on PICC"}, {"91A1", APDUCODE_TYPE_NONE, "Unrecoverable error within application"}, {"91AE", APDUCODE_TYPE_NONE, "Authentication status does not allow the requested command"}, {"91AF", APDUCODE_TYPE_NONE, "Additional data frame is expected to be sent"}, {"91BE", APDUCODE_TYPE_NONE, "Out of boundary"}, {"91C1", APDUCODE_TYPE_NONE, "Unrecoverable error within PICC"}, {"91CA", APDUCODE_TYPE_NONE, "Previous Command was not fully completed"}, {"91CD", APDUCODE_TYPE_NONE, "PICC was disabled by an unrecoverable error"}, {"91CE", APDUCODE_TYPE_NONE, "Number of Applications limited to 28"}, {"91DE", APDUCODE_TYPE_NONE, "File or application already exists"}, {"91EE", APDUCODE_TYPE_NONE, "Could not complete NV-write operation due to loss of power"}, {"91F0", APDUCODE_TYPE_NONE, "Specified file number does not exist"}, {"91F1", APDUCODE_TYPE_NONE, "Unrecoverable error within file"}, {"920x", APDUCODE_TYPE_INFO, "Writing to EEPROM successful after 'x' attempts."}, {"9210", APDUCODE_TYPE_ERROR, "Insufficient memory. No more storage available."}, {"9240", APDUCODE_TYPE_ERROR, "Writing to EEPROM not successful."}, {"9301", APDUCODE_TYPE_NONE, "Integrity error"}, {"9302", APDUCODE_TYPE_NONE, "Candidate S2 invalid"}, {"9303", APDUCODE_TYPE_ERROR, "Application is permanently locked"}, {"9400", APDUCODE_TYPE_ERROR, "No EF selected."}, {"9401", APDUCODE_TYPE_NONE, "Candidate currency code does not match purse currency"}, {"9402", APDUCODE_TYPE_NONE, "Candidate amount too high"}, {"9402", APDUCODE_TYPE_ERROR, "Address range exceeded."}, {"9403", APDUCODE_TYPE_NONE, "Candidate amount too low"}, {"9404", APDUCODE_TYPE_ERROR, "FID not found, record not found or comparison pattern not found."}, {"9405", APDUCODE_TYPE_NONE, "Problems in the data field"}, {"9406", APDUCODE_TYPE_ERROR, "Required MAC unavailable"}, {"9407", APDUCODE_TYPE_NONE, "Bad currency : purse engine has no slot with R3bc currency"}, {"9408", APDUCODE_TYPE_NONE, "R3bc currency not supported in purse engine"}, {"9408", APDUCODE_TYPE_ERROR, "Selected file type does not match command."}, {"9580", APDUCODE_TYPE_NONE, "Bad sequence"}, {"9681", APDUCODE_TYPE_NONE, "Slave not found"}, {"9700", APDUCODE_TYPE_NONE, "PIN blocked and Unblock Try Counter is 1 or 2"}, {"9702", APDUCODE_TYPE_NONE, "Main keys are blocked"}, {"9704", APDUCODE_TYPE_NONE, "PIN not succesfully verified, 3 or more PIN tries left"}, {"9784", APDUCODE_TYPE_NONE, "Base key"}, {"9785", APDUCODE_TYPE_NONE, "Limit exceeded - C-MAC key"}, {"9786", APDUCODE_TYPE_NONE, "SM error - Limit exceeded - R-MAC key"}, {"9787", APDUCODE_TYPE_NONE, "Limit exceeded - sequence counter"}, {"9788", APDUCODE_TYPE_NONE, "Limit exceeded - R-MAC length"}, {"9789", APDUCODE_TYPE_NONE, "Service not available"}, {"9802", APDUCODE_TYPE_ERROR, "No PIN defined."}, {"9804", APDUCODE_TYPE_ERROR, "Access conditions not satisfied, authentication failed."}, {"9835", APDUCODE_TYPE_ERROR, "ASK RANDOM or GIVE RANDOM not executed."}, {"9840", APDUCODE_TYPE_ERROR, "PIN verification not successful."}, {"9850", APDUCODE_TYPE_ERROR, "INCREASE or DECREASE could not be executed because a limit has been reached."}, {"9862", APDUCODE_TYPE_ERROR, "Authentication Error, application specific (incorrect MAC)"}, {"9900", APDUCODE_TYPE_NONE, "1 PIN try left"}, {"9904", APDUCODE_TYPE_NONE, "PIN not succesfully verified, 1 PIN try left"}, {"9985", APDUCODE_TYPE_NONE, "Wrong status - Cardholder lock"}, {"9986", APDUCODE_TYPE_ERROR, "Missing privilege"}, {"9987", APDUCODE_TYPE_NONE, "PIN is not installed"}, {"9988", APDUCODE_TYPE_NONE, "Wrong status - R-MAC state"}, {"9A00", APDUCODE_TYPE_NONE, "2 PIN try left"}, {"9A04", APDUCODE_TYPE_NONE, "PIN not succesfully verified, 2 PIN try left"}, {"9A71", APDUCODE_TYPE_NONE, "Wrong parameter value - Double agent AID"}, {"9A72", APDUCODE_TYPE_NONE, "Wrong parameter value - Double agent Type"}, {"9D05", APDUCODE_TYPE_ERROR, "Incorrect certificate type"}, {"9D07", APDUCODE_TYPE_ERROR, "Incorrect session data size"}, {"9D08", APDUCODE_TYPE_ERROR, "Incorrect DIR file record size"}, {"9D09", APDUCODE_TYPE_ERROR, "Incorrect FCI record size"}, {"9D0A", APDUCODE_TYPE_ERROR, "Incorrect code size"}, {"9D10", APDUCODE_TYPE_ERROR, "Insufficient memory to load application"}, {"9D11", APDUCODE_TYPE_ERROR, "Invalid AID"}, {"9D12", APDUCODE_TYPE_ERROR, "Duplicate AID"}, {"9D13", APDUCODE_TYPE_ERROR, "Application previously loaded"}, {"9D14", APDUCODE_TYPE_ERROR, "Application history list full"}, {"9D15", APDUCODE_TYPE_ERROR, "Application not open"}, {"9D17", APDUCODE_TYPE_ERROR, "Invalid offset"}, {"9D18", APDUCODE_TYPE_ERROR, "Application already loaded"}, {"9D19", APDUCODE_TYPE_ERROR, "Invalid certificate"}, {"9D1A", APDUCODE_TYPE_ERROR, "Invalid signature"}, {"9D1B", APDUCODE_TYPE_ERROR, "Invalid KTU"}, {"9D1D", APDUCODE_TYPE_ERROR, "MSM controls not set"}, {"9D1E", APDUCODE_TYPE_ERROR, "Application signature does not exist"}, {"9D1F", APDUCODE_TYPE_ERROR, "KTU does not exist"}, {"9D20", APDUCODE_TYPE_ERROR, "Application not loaded"}, {"9D21", APDUCODE_TYPE_ERROR, "Invalid Open command data length"}, {"9D30", APDUCODE_TYPE_ERROR, "Check data parameter is incorrect (invalid start address)"}, {"9D31", APDUCODE_TYPE_ERROR, "Check data parameter is incorrect (invalid length)"}, {"9D32", APDUCODE_TYPE_ERROR, "Check data parameter is incorrect (illegal memory check area)"}, {"9D40", APDUCODE_TYPE_ERROR, "Invalid MSM Controls ciphertext"}, {"9D41", APDUCODE_TYPE_ERROR, "MSM controls already set"}, {"9D42", APDUCODE_TYPE_ERROR, "Set MSM Controls data length less than 2 bytes"}, {"9D43", APDUCODE_TYPE_ERROR, "Invalid MSM Controls data length"}, {"9D44", APDUCODE_TYPE_ERROR, "Excess MSM Controls ciphertext"}, {"9D45", APDUCODE_TYPE_ERROR, "Verification of MSM Controls data failed"}, {"9D50", APDUCODE_TYPE_ERROR, "Invalid MCD Issuer production ID"}, {"9D51", APDUCODE_TYPE_ERROR, "Invalid MCD Issuer ID"}, {"9D52", APDUCODE_TYPE_ERROR, "Invalid set MSM controls data date"}, {"9D53", APDUCODE_TYPE_ERROR, "Invalid MCD number"}, {"9D54", APDUCODE_TYPE_ERROR, "Reserved field error"}, {"9D55", APDUCODE_TYPE_ERROR, "Reserved field error"}, {"9D56", APDUCODE_TYPE_ERROR, "Reserved field error"}, {"9D57", APDUCODE_TYPE_ERROR, "Reserved field error"}, {"9D60", APDUCODE_TYPE_ERROR, "MAC verification failed"}, {"9D61", APDUCODE_TYPE_ERROR, "Maximum number of unblocks reached"}, {"9D62", APDUCODE_TYPE_ERROR, "Card was not blocked"}, {"9D63", APDUCODE_TYPE_ERROR, "Crypto functions not available"}, {"9D64", APDUCODE_TYPE_ERROR, "No application loaded"}, {"9E00", APDUCODE_TYPE_NONE, "PIN not installed"}, {"9E04", APDUCODE_TYPE_NONE, "PIN not succesfully verified, PIN not installed"}, {"9F00", APDUCODE_TYPE_NONE, "PIN blocked and Unblock Try Counter is 3"}, {"9F04", APDUCODE_TYPE_NONE, "PIN not succesfully verified, PIN blocked and Unblock Try Counter is 3"}, {"9FXX", APDUCODE_TYPE_NONE, "Command successfully executed; 'xx' bytes of data are available and can be requested using GET RESPONSE."}, {"9XXX", APDUCODE_TYPE_NONE, "Application related status, (ISO 7816-3)"} }; const size_t APDUCodeTableLen = sizeof(APDUCodeTable)/sizeof(APDUCode); int CodeCmp(const char *code1, const char *code2) { int xsymb = 0; int cmp = 0; for (int i = 0; i < 4; i++) { if (code1[i] == code2[i]) cmp++; if (code1[i] == 'X' || code2[i] == 'X') xsymb++; } if (cmp == 4) return 0; if (cmp + xsymb == 4) return xsymb; return -1; } const APDUCode* const GetAPDUCode(uint8_t sw1, uint8_t sw2) { char buf[6] = {0}; int res; int mineq = APDUCodeTableLen; int mineqindx = 0; sprintf(buf, "%02X%02X", sw1, sw2); for (int i = 0; i < APDUCodeTableLen; i++) { res = CodeCmp(APDUCodeTable[i].ID, buf); // equal if (res == 0) { return &APDUCodeTable[i]; } // with some 'X' if (res > 0 && mineq > res) { mineq = res; mineqindx = i; } } // if we have not equal, but with some 'X' if (mineqindx < APDUCodeTableLen) { return &APDUCodeTable[mineqindx]; } return NULL; } const char* GetAPDUCodeDescription(uint8_t sw1, uint8_t sw2) { const APDUCode *cd = GetAPDUCode(sw1, sw2); if (cd) return cd->Description; else return APDUCodeTable[0].Description; //empty string }