1. Validating Proxmark3 client functionality

Table of Contents

If all went well you should get some information about the firmware and memory usage as well as the prompt, something like this.

[=] Session log /home/iceman/.proxmark3/logs/log_20220212.txt
[+] loaded from JSON file /home/iceman/.proxmark3/preferences.json
[=] Using UART port /dev/ttyS3
[=] Communicating with PM3 over USB-CDC


  ██████╗ ███╗   ███╗█████╗
  ██╔══██╗████╗ ████║╚═══██╗
  ██████╔╝██╔████╔██║ ████╔╝
  ██╔═══╝ ██║╚██╔╝██║ ╚══██╗
  ██║     ██║ ╚═╝ ██║█████╔╝
  ╚═╝     ╚═╝     ╚═╝╚════╝     [ Iceman ❄️ ]




 [ Proxmark3 RFID instrument ]

 [ CLIENT ]
  RRG/Iceman/master/v4.14831-252 2022-02-08 05:03:08
  compiled with............. GCC 10.3.0
  platform.................. Linux / x86_64
  Readline support.......... present
  QT GUI support............ present
  native BT support......... absent
  Python script support..... present
  Lua SWIG support.......... present
  Python SWIG support....... present

 [ PROXMARK3 ]
  device.................... RDV4
  firmware.................. RDV4
  external flash............ present
  smartcard reader.......... present
  FPC USART for BT add-on... absent

 [ ARM ]
  bootrom: RRG/Iceman/master/v4.14831-176 2022-02-03 18:35:55
       os: RRG/Iceman/master/v4.14831-205 2022-02-04 21:26:49
  compiled with GCC 9.2.1 20191025 (release) [ARM/arm-9-branch revision 277599]

 [ FPGA ]
  LF image built for 2s30vq100 on 2020-07-08 at 23:08:07
  HF image built for 2s30vq100 on 2020-07-08 at 23:08:19
  HF FeliCa image built for 2s30vq100 on 2020-07-08 at 23:08:30

 [ Hardware ]
  --= uC: AT91SAM7S512 Rev A
  --= Embedded Processor: ARM7TDMI
  --= Internal SRAM size: 64K bytes
  --= Architecture identifier: AT91SAM7Sxx Series
  --= Embedded flash memory 512K bytes ( 59% used )

[usb] pm3 -->

This [usb] pm3 --> is the Proxmark3 interactive prompt.

To get interactive help

^Top

For basic help type help. Or for help on a set of sub commands type the command followed by help. For example hf mf help.

First tests

^Top

These commands will return some info about your Proxmark software and hardware status.

[usb] pm3 --> hw status
[usb] pm3 --> hw version
[usb] pm3 --> hw tune

You are now ready to use your newly flashed proxmark3 device. Many commands uses the h parameter to show a help text.

To quit the client

^Top

[usb] pm3 --> quit

or simple press CTRL-D.

Next steps

^Top

Some configuration steps are still needed.

For the next steps, please read the following pages: