# Notes on Cloner gunes
|
|
|
|
This document is based mostly on information posted on http://www.proxmark.org/forum/viewtopic.php?pid=39903#p39903
|
|
|
|
- [Blue and black cloners](#blue-and-black-cloners)
|
|
- [White cloner (pre 2015)](#white-cloner-pre-2015)
|
|
- [White cloner (after 2016)](#white-cloner-after-2016)
|
|
- [White cloner (after 2016 D Quality)](#white-cloner-after-2016-d-quality)
|
|
- [restore page1 data](#restore-page1-data)
|
|
- [Sniffing the comms](#sniffing-the-comms)
|
|
|
|
|
|
# Blue and black cloners
|
|
|
|
3 variants:
|
|
1. EM cloner
|
|
2. HID cloner
|
|
3. EM/HID cloner
|
|
|
|
Quality varies my manufacturer (Quality A (Good) until D (Bad))
|
|
They set a password on block 7 of the chip and set the password enable bit in block 0
|
|
```
|
|
Standard password is normally: 51243648
|
|
```
|
|
**Be sure to purchase the EM/HID version**
|
|
|
|
# White cloner (pre 2015)
|
|
|
|
Multifrequency
|
|
Buttons light up BLUE
|
|
Reads data correctly
|
|
Coil performance acceptable
|
|
```
|
|
Standard password is normally (for T55xx): AA55BBBB
|
|
Standard password 13,56mHz: individual per white cloner
|
|
```
|
|
|
|
|
|
# White cloner (after 2016)
|
|
Multifrequency
|
|
Buttons light up WHITE
|
|
Data scrambled (variable per individual cloner, possibly due to prevent legal issues)
|
|
Coil performance good
|
|
```
|
|
Standard password is normally (for T55xx): AA55BBBB
|
|
Standard password 13,56mHz: individual per white cloner
|
|
```
|
|
|
|
|
|
# White cloner (after 2016 D Quality)
|
|
Multifrequency (it says so but it doesn't)
|
|
Only works for EM/HID card (125kHz)
|
|
High frequency not working
|
|
```
|
|
Standard password is normally (for T55xx): AA55BBBB
|
|
```
|
|
**Note: Sets the HID card in TEST MODE**
|
|
|
|
|
|
# Restore page1 data
|
|
```
|
|
lf t55xx write b 1 d E0150A48 1
|
|
If t55xx write b 2 d 2D782308 1
|
|
```
|
|
|
|
# Sniffing the comms
|
|
The T55x7 protocol uses a pwm based protocol for writing to tags. In order to make decoding easier try the new command as seen below instead. It will try to extract the data written.
|
|
|
|
```
|
|
-- after threshold limit 20 is triggred, skip 10000 samples before collecting samples.
|
|
lf config s 10000 t 20
|
|
lf t55xx sniff
|
|
|
|
-- if you have a save trace from before, try
|
|
data load xxxxxxx.pm3
|
|
lf t55xx sniff 1
|
|
```
|
|
|
|
It uses the existing `lf sniff` command to collect the data, so setting that first as per normal sniffing is recommended. Once you have a sniff, you can "re-sniff" from the stored sniffed data and try different settings, if you think the data is not clean.
|
|
|
|
As normal, the cloner may write data past the end of the 40K sample buffer. So using the `lf config s <x bytes>` then re-run the sniff to see if there is more data. |